SAMBA içine entegre edilen standartlar sayesinde bina akustiği ölçümleri artık daha kolay. İlgili bilgiler aşağıda verilmiştir:
Building acoustics (SAMBA)
SAMBA is user-oriented software for the convenient performance of measurements and analyses necessary in building acoustics. Apart from reverberation time measurements (already included in the basic scope of SAMURAI), this option allows the source and receiving spectra as well as the background noise signal to be determined. It calculates the insulation for airborne and impact sound according to the standards. The menu navigation optimally supports the user in this work. Measurement, analysis and report functions are integrated into a cohesive and clear user interface. During the measurements performed with SAMBA, the SAMURAI display is also available, e.g. 1/3 octave display for the individual channels. The selectability of the measurement signal (noise or impulse) guarantees optimal results.
SAMBA main features:
Management of source/receiving rooms and transmission paths
Clear navigation including status display
Selectable frequency ranges (e.g. 125 ... 3150 Hz or 50 ... 5000 Hz)
Online display of the current 1/3 octave spectrum in SAMURAI
Measurement of reverberation time spectra and level decay curves
Time history of frequency band
Automatic averaging of several microphones and measurements
Calculation and display of the background noise level from the transmission/reverberation time measurement
Standards integrated:
ISO 140-3 (Laboratory measurements, airborne sound insulation of building elements)
ISO 140-4 (Field measurements, airborne sound insulation between rooms)
ISO 140-5 (Field measurements, airborne sound insulation of facades)
ISO 140-6 (Laboratory measurements, impact sound insulation of floors)
ISO 140-7 (Field measurements, impact sound insulation of floors)
ISO 140-8 (Laboratory measurements, reduction of transmitted impact noise by floor coverings)
ISO 140-12 (Laboratory measurements, room-to-room airborne and impact sound insulation)
ISO 717-1 (Rating, airborne sound insulation)
ISO 717-2 (Rating, impact sound insulation)
ISO 3382 (Measurements, reverberation time of rooms)
DIN 4109 (Requirements and testing, sound insulation in buildings)
DIN 4109-10 (Recommendations, enhanced sound insulation in apartments)
Usage of internal or external generators
Flexible creation of a measurement report including form and result export
Option to control the measurement sequence remotely
Creation and printing of the measurement protocols according to the standard